Résultats refractifs et évaluation de la précision du positionnement des implants toriques à l'aide d'un système d'alignement automatisé
dc.rights.license | open | en_US |
dc.contributor.author | CORNUT, T. | |
dc.contributor.author | TOUBOUL, D. | |
dc.contributor.author | ROUGLAN, S. | |
dc.contributor.author | TELLOUCK, L. | |
dc.contributor.author | TELLOUCK, J. | |
hal.structure.identifier | Bordeaux population health [BPH] | |
dc.contributor.author | KOROBELNIK, Jean-Francois
ORCID: 0000-0002-4438-9535 IDREF: 028739272 | |
hal.structure.identifier | Bordeaux population health [BPH] | |
dc.contributor.author | SCHWEITZER, Cedric
ORCID: 0000-0002-2162-9479 IDREF: 133631583 | |
dc.date.accessioned | 2020-11-02T10:17:12Z | |
dc.date.available | 2020-11-02T10:17:12Z | |
dc.date.issued | 2018-04-20 | |
dc.identifier.issn | 1773-0597 (Electronic) 0181-5512 (Linking) | en_US |
dc.identifier.uri | https://oskar-bordeaux.fr/handle/20.500.12278/11568 | |
dc.description.abstractEn | PURPOSE: To compare precision in toric intraocular lens (TIOL) alignment and refractive outcomes between an intraoperative automated digital marker system and the conventional manual-ink marking. MATERIALS AND METHODS: Prospective single center study including consecutive patients undergoing uneventful cataract surgery with corneal astigmatism greater than 1 diopter. Total corneal astigmatism was measured using a placido-dual Scheimpflug system (GalileiG4((R)), Ziemer). Acrysof((R)) SN6AT (Alcon) TIOL's were implanted, and patients were divided into 2 groups, the digital group (Verion((R)), Alcon) and the ink-marking group (Pendular marker, AMO). Mean error in TIOL axis, visual acuity and residual astigmatism were analyzed at 3 days, one month and 6 months after surgery. RESULTS: In total, 45 eyes of 30 patients were included (n=25 digital group, n=20 ink-marking group). The mean preoperative total corneal astigmatism was 1.71+/-0.53 diopters. At one month, there was a significantly lower mean average error in TIOL axis in the digital group compared to the ink-marking group (2.6+/-2.3 degrees and 6.4+/-2.8 degrees respectively, P=0.009). At 6months, these results remained statistically significant. Mean residual astigmatism was 0.7+/-0.4 diopters at one month, without significant difference between the two groups (P=0.9). The rate of misalignment less than or equal to 5 degrees was 86 % (n=25) in the digital group and 63 % (n=20) in the ink-marking group (P=0.05). CONCLUSION: Intraoperative digital marker system is associated with better TIOL alignment accuracy and better reproducibility than the manual ink-marking method. | |
dc.language.iso | EN | en_US |
dc.subject.en | LEHA | |
dc.title | Résultats refractifs et évaluation de la précision du positionnement des implants toriques à l'aide d'un système d'alignement automatisé | |
dc.title.alternative | J Fr Ophtalmol | en_US |
dc.type | Article de revue | en_US |
dc.identifier.doi | 10.1016/j.jfo.2017.09.012 | en_US |
dc.subject.hal | Sciences du Vivant [q-bio]/Santé publique et épidémiologie | en_US |
dc.identifier.pubmed | 29685740 | en_US |
bordeaux.journal | Journal Français D'Ophtalmologie | en_US |
bordeaux.page | 291-301 | en_US |
bordeaux.volume | 41 | en_US |
bordeaux.hal.laboratories | Bordeaux Population Health Research Center (BPH) - UMR 1219 | en_US |
bordeaux.issue | 4 | en_US |
bordeaux.institution | Université de Bordeaux | en_US |
bordeaux.team | LEHA_BPH | |
bordeaux.peerReviewed | oui | en_US |
bordeaux.inpress | non | en_US |
hal.identifier | hal-03194250 | |
hal.version | 1 | |
hal.date.transferred | 2021-04-09T12:06:30Z | |
hal.export | true | |
bordeaux.COinS | ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.title=R%C3%A9sultats%20refractifs%20et%20%C3%A9valuation%20de%20la%20pr%C3%A9cision%20du%20positionnement%20des%20implants%20toriques%20%C3%A0%20l'aide%20d'un%20syst%C3%A8me%20&rft.atitle=R%C3%A9sultats%20refractifs%20et%20%C3%A9valuation%20de%20la%20pr%C3%A9cision%20du%20positionnement%20des%20implants%20toriques%20%C3%A0%20l'aide%20d'un%20syst%C3%A8me%2&rft.jtitle=Journal%20Fran%C3%A7ais%20D'Ophtalmologie&rft.date=2018-04-20&rft.volume=41&rft.issue=4&rft.spage=291-301&rft.epage=291-301&rft.eissn=1773-0597%20(Electronic)%200181-5512%20(Linking)&rft.issn=1773-0597%20(Electronic)%200181-5512%20(Linking)&rft.au=CORNUT,%20T.&TOUBOUL,%20D.&ROUGLAN,%20S.&TELLOUCK,%20L.&TELLOUCK,%20J.&rft.genre=article |
Fichier(s) constituant ce document
Fichiers | Taille | Format | Vue |
---|---|---|---|
Il n'y a pas de fichiers associés à ce document. |