Afficher la notice abrégée

dc.contributor.advisorEric Arquis
dc.contributor.advisorCédric Le Bot
hal.structure.identifierInstitut de Mécanique et d'Ingénierie de Bordeaux [I2M]
dc.contributor.authorDURAND-ESTEBE, Baptiste
dc.contributor.otherChristophe Marvillet [Président]
dc.contributor.otherPatrice Joubert [Rapporteur]
dc.contributor.otherBenoît Stutz [Rapporteur]
dc.contributor.otherJean Moureh
dc.contributor.otherJean-Rodolphe Puiggali
dc.date.accessioned2021-05-14T09:56:23Z
dc.date.available2021-05-14T09:56:23Z
dc.identifier.urihttps://oskar-bordeaux.fr/handle/20.500.12278/77781
dc.identifier.nnt2014BORD0088
dc.description.abstractDe nos, jours avec la démocratisation des équipements électroniques et l’explosions des services informatiques proposés sur le web, la consommation des datacenters devient un enjeu énergétique et économique majeur. Ce terme qui peut être traduit par « centre de calcul », désigne les infrastructures qui hébergent et font fonctionner en permanence des serveurs informatiques. Son rôle est de fournir aux équipements électroniques un environnement thermique adapté, ainsi qu’une alimentation électrique stable de manière à assurer une très grande sécurité de fonctionnement. Mais l’activité permanente des serveurs génère de grandes quantités de chaleurs, et un refroidissement permanent est nécessaire. Cette étude à pour objectif de mieux comprendre les phénomènes physiques qui interviennent dans le fonctionnement des datacenters afin d’apporter des solutions pour optimiser leur fonctionnement et diminuer leur consommation. A l’aide de simulations numériques, nous étudions les écoulements d’air et les transferts de chaleur qui interviennent dans la salle informatique, et nous proposons un nouveau modèle numérique qui permet de simuler le comportement des serveurs de nouvelle génération. Puis, grâce à une méthode de type POD, couplée au logiciel TRNSYS, nous développons un modèle « transversal » capable de simuler le fonctionnement complet d’un centre de calcul depuis les équipements informatiques, jusqu’au système de production d’air froid. Finalement, ce dernier est employé pour concevoir et tester un système de régulation adaptatif qui permet de réduire significativement les consommations d’énergie.
dc.description.abstractEnNowadays, with the constant evolution of Information Technology (IT) equipments, the energy consumption of datacenter over the world becomes a major concern. These infrastructures are designed to provide an adapted thermal environment and an uninterrupted power supply to the IT servers, in order to guarantee a high level of reliability. However, the constant activity of electronic equipments releases a large amount of heat, and requires a constant cooling. Thus the objective of this work is to study the physical phenomena involved in an operating datacenter, in order to optimize the process and to reduce its energy consumption. Using numerical simulation, we study the air flow and the heat transfers happening in the servers’ room. To quantify the impact of new generation servers on the cooling process, we propose a numerical model that simulates the behavior of “blade” server. Then, using a Proper Orthogonal Decomposition (POD) method linked to the software TRNSYS, we propose a new “transversal” model, that simulates a datacenter behavior from the servers to the cooling plant. This model is used to develop a new adaptive regulation strategy, which constantly optimizes the system in order to ensure a safe thermal environment, and provides large energy savings.
dc.language.isofr
dc.subjectSimulation
dc.subjectDatacenters
dc.subjectRefroidissement
dc.subjectCFD
dc.subjectFree-cooling
dc.subjectPOD
dc.subject.enPOD
dc.subject.enEconomizer
dc.subject.enFree-cooling
dc.subject.enCFD
dc.subject.enSimulation
dc.subject.enDatacenters
dc.subject.enCooling plant
dc.titleOptimisation énergétique du rafraichissement des datacenters
dc.title.enEnergy optimization of datacenters cooling process
dc.typeThèses de doctorat
dc.subject.halPhysique [physics]/Physique [physics]
bordeaux.hal.laboratoriesInstitut de Mécanique et d’Ingénierie de Bordeaux (I2M) - UMR 5295*
bordeaux.institutionUniversité de Bordeaux
bordeaux.institutionBordeaux INP
bordeaux.institutionCNRS
bordeaux.institutionINRAE
bordeaux.institutionArts et Métiers
bordeaux.type.institutionUniversité de Bordeaux
bordeaux.ecole.doctoraleÉcole doctorale des sciences physiques et de l’ingénieur (Talence, Gironde)
hal.identifiertel-01175938
hal.version1
hal.origin.linkhttps://hal.archives-ouvertes.fr//tel-01175938v1
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.title=Optimisation%20%C3%A9nerg%C3%A9tique%20du%20rafraichissement%20des%20datacenters&rft.atitle=Optimisation%20%C3%A9nerg%C3%A9tique%20du%20rafraichissement%20des%20datacenters&rft.au=DURAND-ESTEBE,%20Baptiste&rft.genre=unknown


Fichier(s) constituant ce document

FichiersTailleFormatVue

Il n'y a pas de fichiers associés à ce document.

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée