Afficher la notice abrégée

hal.structure.identifierInstitut de Recherche de l'Ecole Navale [IRENAV]
dc.contributor.authorSCUILLER, Franck
dc.date.accessioned2021-05-14T09:55:11Z
dc.date.available2021-05-14T09:55:11Z
dc.date.issued2012-10
dc.date.conference2012-10
dc.identifier.urihttps://oskar-bordeaux.fr/handle/20.500.12278/77669
dc.descriptionOn a shipboard electric power system, in steady-state operations, the electric grid disturbances due to powerfull periodic pulsed loads are estimated by the voltage and frequency modulations. Energy Storage System (ESS) with fast discharge ability allows to reduce the stress on the grid components and to meet the design standard requirements. This paper focuses on the sizing and simulation of a supercapacitor ESS (SC ESS). Regarding the chosen topology, the SC bank is directly connected to the grid converter (without DC bus stage) because reliability, efficiency and ability to ensure other functions (as voltage sag mitigations) are expected. Regarding the SC ESS management, the DC voltage is controlled at any time and SC ESS charge and discharge are ordered by stepping the reference DC voltage to minimal value or maximal value. Furthermore SC ESS charge/discharge cycle is synchronized with the pulsed load with a smooth time advance in order to compensate the lower power rise of the ESS in comparison with the one of the pulsed load. The results obtained with the shipgrid simulator are convincing: the frequency modulation is significantly reduced (by more three times) and becomes compliant with the standard requirement. Regarding the generator side, the governor torque variations are strongly mitigated.
dc.description.abstractEnOn a shipboard electric power system, in steady-state operations, the electric grid disturbances due to powerfull periodic pulsed loads are estimated by the voltage and frequency modulations. Energy Storage System (ESS) with fast discharge ability allows to reduce the stress on the grid components and to meet the design standard requirements. This paper focuses on the sizing and simulation of a supercapacitor ESS (SC ESS). Regarding the chosen topology, the SC bank is directly connected to the grid converter (without DC bus stage) because reliability, efficiency and ability to ensure other functions (as voltage sag mitigations) are expected. Regarding the SC ESS management, the DC voltage is controlled at any time and SC ESS charge and discharge are ordered by stepping the reference DC voltage to minimal value or maximal value. Furthermore SC ESS charge/discharge cycle is synchronized with the pulsed load with a smooth time advance in order to compensate the lower power rise of the ESS in comparison with the one of the pulsed load. The results obtained with the shipgrid simulator are convincing: the frequency modulation is significantly reduced (by more three times) and becomes compliant with the standard requirement. Regarding the generator side, the governor torque variations are strongly mitigated.
dc.language.isoen
dc.publisherIEEE
dc.source.titleIECON 2012
dc.subject.enShipboard electric power system
dc.subject.enSupercapacitor
dc.subject.enElectrical grid simulation
dc.subject.enDeviation factor
dc.subject.enFrequency modulation
dc.subject.enPulsed load
dc.subject.enHarmonics
dc.title.enStudy of a supercapacitor Energy Storage System designed to reduce frequency modulation on shipboard electric power system
dc.typeCommunication dans un congrès avec actes
dc.identifier.doi10.1109/IECON.2012.6388938
dc.subject.halSciences de l'ingénieur [physics]/Energie électrique
bordeaux.page4054 - 4059
bordeaux.hal.laboratoriesInstitut de Mécanique et d’Ingénierie de Bordeaux (I2M) - UMR 5295*
bordeaux.institutionUniversité de Bordeaux
bordeaux.institutionBordeaux INP
bordeaux.institutionCNRS
bordeaux.institutionINRAE
bordeaux.institutionArts et Métiers
bordeaux.countryCA
bordeaux.title.proceeding38th Annual Conference on IEEE Industrial Electronics Society
bordeaux.conference.cityMontreal
bordeaux.peerReviewedoui
hal.identifierhal-01208370
hal.version1
hal.origin.linkhttps://hal.archives-ouvertes.fr//hal-01208370v1
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.btitle=IECON%202012&rft.date=2012-10&rft.spage=4054%20-%204059&rft.epage=4054%20-%204059&rft.au=SCUILLER,%20Franck&rft.genre=proceeding


Fichier(s) constituant ce document

FichiersTailleFormatVue

Il n'y a pas de fichiers associés à ce document.

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée