Afficher la notice abrégée

dc.contributor.advisorFeugeas, Jean-Luc
dc.contributor.advisorKantor, Guy
dc.contributor.authorCARON, Jérôme
dc.contributor.otherFeugeas, Jean-Luc
dc.contributor.otherKantor, Guy
dc.contributor.otherKieffer, Jean-Claude
dc.contributor.otherCarlan, Loïc de
dc.contributor.otherFranceries, Xavier
dc.contributor.otherNicolaï, Philippe
dc.contributor.otherTikhonchuk, Vladimir
dc.contributor.otherSuraud, Éric
dc.contributor.otherDejean-Viellard, Catherine
dc.contributor.otherFerrand, Régis
dc.date2016-12-07
dc.identifier.urihttp://www.theses.fr/2016BORD0452/abes
dc.identifier.uri
dc.identifier.urihttps://tel.archives-ouvertes.fr/tel-01577853
dc.identifier.nnt2016BORD0452
dc.description.abstractEn radiothérapie externe, les simulations des dépôts de dose aux patients sont réalisées sur des systèmesde planification de traitement (SPT) dotés d'algorithmes de calcul qui diffèrent dans leur modélisationdes processus physiques d'interaction des électrons et des photons. Or ces SPT, bien que rapides enclinique, montrent parfois des erreurs significatives aux abords des hétérogénéités du corps humain. Montravail de thèse a consisté à valider le modèle aux moments entropique M1 pour des faisceaux d'électronscliniques. Cet algorithme développé au CELIA dans le cadre de la physique des plasmas repose sur larésolution de l'équation cinétique de transport de Boltzmann linéarisée selon une décomposition auxmoments. M1 nécessite une fermeture du système d'équations basée sur le H-Théorème (maximisationde l'entropie). Les cartographies de dose 1D de faisceaux d'électrons de 9 et 20 MeV issues de M1 ontété comparées à celles issues de codes de référence : macro Monte-Carlo clinique (eMC) et full Monte-Carlo (GEANT-MCNPX) ainsi qu'à des données expérimentales. Les cas tests consistent en des fantômesd'abord homogènes puis de complexité croissante avec insertion d'hétérogéenéités mimant les tissus osseuxet pulmonaire. In fine, le modèle aux moments M1 démontre des propriétés de précision meilleures quecertains algorithmes de type Pencil Beam Kernel encore utilisés cliniquement et proches de celles fourniespar des codes full Monte-Carlo académiques ou macro Monte-Carlo cliniques, même dans les cas testscomplexes retenus. Les performances liées aux temps de calcul de M1 ont été évaluées comme étantmeilleures que celles de codes Monte-Carlo.
dc.description.abstractEnIn radiotherapy field, dose deposition simulations in patients are performed on Treatment Planning Systems (TPS) equipped with specific algorithms that differ in the way they model the physical interaction processes of electrons and photons. Although those clinical TPS are fast, they show significant discrepancies in the neighbooring of inhomogeneous tissues. My work consisted in validating for clinical electron beams an entropic moments based algorithm called M1. Develelopped in CELIA for warm and dense plasma simulations, M1 relies on the the resolution of the linearized Boltzmann kinetic equation for particles transport according to a moments decomposition. M1 equations system requires a closure based on H-Theorem (entropy maximisation). M1 dose deposition maps of 9 and 20 MeV electron beams simulations were compared to those extracted from reference codes simulations : clinical macro Monte-Carlo (eMC) and full Monte-carlo (GEANT4-MCNPX) codes and from experimental data as well. The different test cases consisted in homogeneous et complex inhomogeneous fantoms with bone and lung inserts. We found that M1 model provided a dose deposition accuracy better than some Pencil Beam Kernel algorithm and close of those furnished by clinical macro and academic full Monte-carlo codes, even in the worst inhomogeneous cases. Time calculation performances were also investigated and found better than the Monte-Carlo codes.
dc.language.isofr
dc.subjectRadiothérapie externe
dc.subjectSystème de planification de traitement
dc.subjectModèle aux moments entropique
dc.subjectAlgorithmes déterministes
dc.subjectCodes Monte-Carlo
dc.subject.enExternal radiotherapy
dc.subject.enTreatment Planning System
dc.subject.enEntropic model
dc.subject.enMoments based model
dc.subject.enDeterministic algorithm
dc.subject.enMonte-Carlo code
dc.titleEtude et validation clinique d'un modèle aux moments entropique pour le transport de particules énergétiques : application aux faisceaux d'électrons pour la radiothérapie externe
dc.title.enStudy and clinical validation of a deterministic moments based algorithm dedicated to the energetic particles transport simulations : application to the electron beams in external radiotherapy
dc.typeThèses de doctorat
dc.contributor.jurypresidentKieffer, Jean-Claude
bordeaux.hal.laboratoriesCentre Lasers Intenses et Applications (Bordeaux)
bordeaux.type.institutionBordeaux
bordeaux.thesis.disciplineAstrophysique, plasmas, nucléaire
bordeaux.ecole.doctoraleÉcole doctorale des sciences physiques et de l’ingénieur (Talence, Gironde)
star.origin.linkhttps://www.theses.fr/2016BORD0452
dc.contributor.rapporteurCarlan, Loïc de
dc.contributor.rapporteurFranceries, Xavier
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.title=Etude%20et%20validation%20clinique%20d'un%20mod%C3%A8le%20aux%20moments%20entropique%20pour%20le%20transport%20de%20particules%20%C3%A9nerg%C3%A9tiques%20:%20application%&rft.atitle=Etude%20et%20validation%20clinique%20d'un%20mod%C3%A8le%20aux%20moments%20entropique%20pour%20le%20transport%20de%20particules%20%C3%A9nerg%C3%A9tiques%20:%20application&rft.au=CARON,%20Je%CC%81ro%CC%82me&rft.genre=unknown