Artificial intelligence in CT for quantifying lung changes in the era of CFTR modulators
DOURNES, Gael
Centre de recherche Cardio-Thoracique de Bordeaux [Bordeaux] [CRCTB]
CIC Bordeaux
Centre Hospitalier Universitaire de Bordeaux [CHU Bordeaux]
See more >
Centre de recherche Cardio-Thoracique de Bordeaux [Bordeaux] [CRCTB]
CIC Bordeaux
Centre Hospitalier Universitaire de Bordeaux [CHU Bordeaux]
DOURNES, Gael
Centre de recherche Cardio-Thoracique de Bordeaux [Bordeaux] [CRCTB]
CIC Bordeaux
Centre Hospitalier Universitaire de Bordeaux [CHU Bordeaux]
Centre de recherche Cardio-Thoracique de Bordeaux [Bordeaux] [CRCTB]
CIC Bordeaux
Centre Hospitalier Universitaire de Bordeaux [CHU Bordeaux]
DENIS DE SENNEVILLE, Baudouin
Institut de Mathématiques de Bordeaux [IMB]
Modélisation Mathématique pour l'Oncologie [MONC]
Institut de Mathématiques de Bordeaux [IMB]
Modélisation Mathématique pour l'Oncologie [MONC]
BERGER, Patrick
Centre de recherche Cardio-Thoracique de Bordeaux [Bordeaux] [CRCTB]
CIC Bordeaux
Centre Hospitalier Universitaire de Bordeaux [CHU Bordeaux]
Centre de recherche Cardio-Thoracique de Bordeaux [Bordeaux] [CRCTB]
CIC Bordeaux
Centre Hospitalier Universitaire de Bordeaux [CHU Bordeaux]
LAURENT, François
Centre de recherche Cardio-Thoracique de Bordeaux [Bordeaux] [CRCTB]
CIC Bordeaux
Centre Hospitalier Universitaire de Bordeaux [CHU Bordeaux]
Centre de recherche Cardio-Thoracique de Bordeaux [Bordeaux] [CRCTB]
CIC Bordeaux
Centre Hospitalier Universitaire de Bordeaux [CHU Bordeaux]
BENLALA, Ilyes
Centre de recherche Cardio-Thoracique de Bordeaux [Bordeaux] [CRCTB]
CIC Bordeaux
Centre Hospitalier Universitaire de Bordeaux [CHU Bordeaux]
< Reduce
Centre de recherche Cardio-Thoracique de Bordeaux [Bordeaux] [CRCTB]
CIC Bordeaux
Centre Hospitalier Universitaire de Bordeaux [CHU Bordeaux]
Language
en
Article de revue
This item was published in
European Respiratory Journal. 2022, vol. 59, p. 2100844
European Respiratory Society
English Abstract
Background: Chest computed tomography (CT) remains the imaging standard for demonstrating cystic fibrosis (CF) airway structural disease in vivo. However, visual scoring systems as an outcome measure are time consuming, ...Read more >
Background: Chest computed tomography (CT) remains the imaging standard for demonstrating cystic fibrosis (CF) airway structural disease in vivo. However, visual scoring systems as an outcome measure are time consuming, require training and lack high reproducibility. Our objective was to validate a fully automated artificial intelligence (AI)-driven scoring system of CF lung disease severity.Methods: Data were retrospectively collected in three CF reference centres, between 2008 and 2020, in 184 patients aged 4-54 years. An algorithm using three 2D convolutional neural networks was trained with 78 patients' CT scans (23 530 CT slices) for the semantic labelling of bronchiectasis, peribronchial thickening, bronchial mucus, bronchiolar mucus and collapse/consolidation. 36 patients' CT scans (11 435 CT slices) were used for testing versus ground-truth labels. The method's clinical validity was assessed in an independent group of 70 patients with or without lumacaftor/ivacaftor treatment (n=10 and n=60, respectively) with repeat examinations. Similarity and reproducibility were assessed using the Dice coefficient, correlations using the Spearman test, and paired comparisons using the Wilcoxon rank test.Results: The overall pixelwise similarity of AI-driven versus ground-truth labels was good (Dice 0.71). All AI-driven volumetric quantifications had moderate to very good correlations to a visual imaging scoring (p<0.001) and fair to good correlations to forced expiratory volume in 1 s % predicted at pulmonary function tests (p<0.001). Significant decreases in peribronchial thickening (p=0.005), bronchial mucus (p=0.005) and bronchiolar mucus (p=0.007) volumes were measured in patients with lumacaftor/ivacaftor. Conversely, bronchiectasis (p=0.002) and peribronchial thickening (p=0.008) volumes increased in patients without lumacaftor/ivacaftor. The reproducibility was almost perfect (Dice >0.99).Conclusion: AI allows fully automated volumetric quantification of CF-related modifications over an entire lung. The novel scoring system could provide a robust disease outcome in the era of effective CF transmembrane conductance regulator modulator therapy.Read less <
ANR Project
Translational Research and Advanced Imaging Laboratory - ANR-10-LABX-0057
Origin
Hal imported