How impedance measurements and imaging can be used to characterize the conductivity of tissues during the workflow of an electroporation-based therapy
TASU, J.-P.
Centre hospitalier universitaire de Poitiers = Poitiers University Hospital [CHU de Poitiers [La Milétrie]]
Laboratoire de Traitement de l'Information Medicale [LaTIM]
See more >
Centre hospitalier universitaire de Poitiers = Poitiers University Hospital [CHU de Poitiers [La Milétrie]]
Laboratoire de Traitement de l'Information Medicale [LaTIM]
TASU, J.-P.
Centre hospitalier universitaire de Poitiers = Poitiers University Hospital [CHU de Poitiers [La Milétrie]]
Laboratoire de Traitement de l'Information Medicale [LaTIM]
< Reduce
Centre hospitalier universitaire de Poitiers = Poitiers University Hospital [CHU de Poitiers [La Milétrie]]
Laboratoire de Traitement de l'Information Medicale [LaTIM]
Language
en
Article de revue
This item was published in
IEEE Transactions on Biomedical Engineering. 2023p. 1-9
Institute of Electrical and Electronics Engineers
English Abstract
In this paper we investigate the possibility of using needles, which the interventional radiologist inserts near a deep-seated tumor during an electroporation-based therapy, to characterize the electrical conductivity of ...Read more >
In this paper we investigate the possibility of using needles, which the interventional radiologist inserts near a deep-seated tumor during an electroporation-based therapy, to characterize the electrical conductivity of patient's tissues. Specifically, we propose to exploit voltage/current measurements and imaging that are performed prior to the application of electroporation pulses. The approach is partly based on the concepts of electrical impedance tomography; however, imaging is used to build a specific geometric model and compensate for the lack of information resulting from the small number of electrodes available. 3D canonical and clinical examples, where a few electrodes surround a tumor, demonstrate the feasibility of this method: solving the inverse problem to estimate tissues conductivity converges in a few iterations. For a given error on the measurement, it is also possible to calculate the error on the estimated conductivities. The uncertainty error with clinical data is at best 5% for one of the tissues identified, due to the limitations of the clinical device used. Various improvements to clinical devices are discussed to make the conductivity estimation more accurate but also to extract more information.Read less <
English Keywords
Electrical impedance tomography
Tumors
Conductivity Problem
Imaging
Needles
Electroporation
DC electrical conductivity