dc.description.abstractEnPurpose - Nowadays, distributed generation and microgrids (MGs) are becoming an important research line because of their peculiar characteristics. MGs are composed of small power sources which can be renewable, placed near customer sites. Moreover, they have the inherent property of islanding: the disconnection of either the MG from the main grid or a part of a MG from the rest of the MG. The purpose of this paper is to study two different control strategies allowing grid connected and islanding operation of the MG. Design/methodology/approach - In this paper, the behaviour of a particular MG during grid connected and islanding operation is investigated. The studied MG is based on different energy sources: a wind turbine, a photovoltaic array, a backup diesel generator and a storage system. The renewable sources and the storage system are connected on a DC bus which is interconnected with a main grid through a voltage source inverter (VSI). The attention focuses on the control technique of the VSI during grid connected and islanding operation of the MG. The behaviour of the AC signals on the point of common coupling between the MG and the main grid as well as the DC signals on the DC bus on which are connected renewable energy sources of the MG has been investigated by simulation using a MATLAB/Simulink model. Findings - For the investigated MG, the simulation results show that using a single master VSI and classical control strategies, it is possible to have a good power quality on the MG during grid connection and islanding operation. Originality/value - This paper investigates the behaviour of a particular MG in order to analyse two different control strategies allowing grid connected and islanding operation.
dc.language.isoENen_US
dc.subject.enControl technology
dc.subject.enElectric power generation
dc.subject.enEnergy supply systems
dc.title.enControl of Power Converters for Microgrids
dc.typeArticle de revueen_US
dc.identifier.doi10.1108/03321641111091575en_US
dc.subject.halSciences de l'ingénieur [physics]/Energie électriqueen_US
bordeaux.journalCOMPEL: The International Journal for Computation and Mathematics in Electrical and Electronic Engineeringen_US
bordeaux.page300 - 309en_US
bordeaux.volume30en_US
bordeaux.hal.laboratoriesESTIA - Rechercheen_US
bordeaux.issue1en_US
bordeaux.institutionUniversité de Bordeauxen_US
bordeaux.institutionBordeaux INPen_US
bordeaux.institutionBordeaux Sciences Agroen_US
bordeaux.peerReviewedouien_US
bordeaux.inpressnonen_US
bordeaux.import.sourcehal
hal.identifierhal-00659067
hal.version1
hal.popularnonen_US
hal.audienceInternationaleen_US
hal.exportfalse
workflow.import.sourcehal
dc.rights.ccPas de Licence CCen_US
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=COMPEL:%20The%20International%20Journal%20for%20Computation%20and%20Mathematics%20in%20Electrical%20and%20Electronic%20Engineering&rft.date=2010-03-25&rft.volume=30&rft.issue=1&rft.spage=300%20-%20309&rft.epage=300%20-%20309&rft.eissn=0332-1649&rft.issn=0332-1649&rft.au=VECHIU,%20Ionel&CUREA,%20Octavian&LLARIA,%20Alvaro&CAMBLONG,%20Haritza&rft.genre=article


Fichier(s) constituant ce document

FichiersTailleFormatVue

Il n'y a pas de fichiers associés à ce document.

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée