Mostrar el registro sencillo del ítem

dc.rights.licenseopenen_US
hal.structure.identifierBordeaux population health [BPH]
dc.contributor.authorJOMAA, Emilie
hal.structure.identifierBordeaux population health [BPH]
dc.contributor.authorKOUDSIE, S.
hal.structure.identifierBordeaux population health [BPH]
dc.contributor.authorGONTIER, Brigitte
hal.structure.identifierBordeaux population health [BPH]
dc.contributor.authorROUGIER, Marie Benedicte
hal.structure.identifierBordeaux population health [BPH]
dc.contributor.authorGATTOUSSI, Sarra
ORCID: 0000-0002-8905-7112
hal.structure.identifierBordeaux population health [BPH]
dc.contributor.authorSEGUY, P. H.
hal.structure.identifierBordeaux population health [BPH]
dc.contributor.authorAZAR, M.
hal.structure.identifierBordeaux population health [BPH]
dc.contributor.authorKOROBELNIK, Jean-Francois
ORCID: 0000-0002-4438-9535
IDREF: 028739272
hal.structure.identifierBordeaux population health [BPH]
dc.contributor.authorDELYFER, Marie-Noelle
dc.date.accessioned2023-03-15T10:45:03Z
dc.date.available2023-03-15T10:45:03Z
dc.date.issued2023-04
dc.identifier.issn1773-0597 (Electronic) 0181-5512 (Linking)en_US
dc.identifier.urihttps://oskar-bordeaux.fr/handle/20.500.12278/172317
dc.description.abstractIntroduction : Les implants corticoïdes à libération prolongée sont injectés dans la cavité vitréenne à l’aide de stylos préchargés. L’implant de fluocinolone (FAc) se caractérise par une taille environ deux fois inférieure à celle de celui de dexaméthasone (Dex-I). Il est également simplement « déposé » dans la base du vitré et non propulsé dans la cavité vitréenne comme le Dex-I. Le contrôle de son bon positionnement après injection est de ce fait très difficile en ophtalmoscopie indirecte. Notre étude a pour objectif de comparer les performances des différents examens disponibles pour confirmer la présence dans la cavité vitréenne du FAc après injection. Méthodes : Douze yeux de 12 patients consécutifs ont été inclus dans une étude rétrospective monocentrique, observationnelle, réalisée au CHU de Bordeaux. Les patients ont tous bénéficié de l’injection du FAc après dilatation pupillaire, puis d’un fond d’œil, d’une rétinographie grand-champ (Clarus®, Carl-Zeiss-Meditec, Dublin, CA, USA) et d’une rétinographie ultra-grand-champ (California®, Optos, Edinbourg, Royaume-Uni). Sept jours après, une échographie en mode-B (10 MHz, AVISO, Quantel-medical, France) et une échographie UBM (50 MHz, AVISO, Quantel-medical, France) ont été réalisées. Résultats : Le fond d’œil et la rétinographie grand-champ ont permis d’observer 4/12 implants (33,3 %). La rétinophotographie ultra-grand-champ a permis de détecter 6/12 implants (50 %). Tous les implants vus au fond d’œil et en rétinographie grand-champ ont été également visualisés avec l’ultra-grand-champ. L’échographie en mode-B a mis en évidence 5/12 implants (41,6 %) et l’UBM 9/12 implants (75 %). Enfin, un implant a migré en chambre antérieure et a pu être mis en évidence dans l’angle irido-cornéen en gonioscopie. Conclusion : La confirmation objective du bon positionnement de l’implant FAc est essentielle. S’il n’est pas visible au simple FO et à l’examen du segment antérieur, la rétinographie ultra-grand-champ puis l’échographie UBM apparaissent comme étant les deux meilleures modalités d’imagerie.
dc.description.abstractEnINTRODUCTION: Sustained-release corticosteroid implants are injected into the vitreous cavity using preloaded pens. The fluocinolone (FAc) implant is approximately half the size of the dexamethasone implant (Dex-I). It is simply introduced in the vitreous base rather than propelled into the vitreous cavity as is Dex-I. Verification of its positioning after injection is thus difficult by indirect ophthalmoscopy. The goal of our study is to compare the performance of available clinical and imaging tools to confirm the presence of the FAc in the vitreous cavity following injection. METHODS: Twelve eyes of 12 consecutive patients were included in a retrospective, single-center, observational study carried out at the Bordeaux University Hospital, France. All patients were injected with the FAc after pupil dilation, and presence of the implant was immediately checked by indirect biomicroscopy, wide-field retinography (Clarus®, Carl-Zeiss-Meditec, Dublin, CA, USA) and ultra-wide-field retinography (California®, Optos, Edinburgh, United-Kingdom). Seven days later, a B-mode ultrasonography (10MHz, AVISO, Quantel-medical, France) and an UBM ultrasonography (50MHz, AVISO, Quantel-medical, France) were performed. RESULTS: Indirect biomicroscopy and wide-field retinography detected 4/12 implants (33.3%). Ultra-wide-field retinophotography detected 6/12 implants (50%). All the implants seen using indirect biomicroscopy and wide-field retinography were also visualized with ultra-wide-field. B-mode ultrasonography showed 5/12 implants (41.6%) and UBM 9/12 implants (75%). Finally, one implant dislocated into the anterior chamber and was seen in the iridocorneal angle on gonioscopy. CONCLUSION: Objective confirmation of the proper positioning of the FAc implant in the vitreous cavity is mandatory. If both indirect ophthalmoscopy and anterior examination fail to detect it, ultra-wide field retinography along with UBM ultrasonography, if necessary, appear to be the two best imaging modalities to use.
dc.language.isoFRen_US
dc.titleComparaison des moyens clinique et d’imagerie disponibles en pratique clinique pour objectiver la présence de l’implant d’acétonide de fluocinolone (Iluvien®) dans la cavité vitréenne après injection.
dc.title.alternativeJ Fr Ophtalmolen_US
dc.typeArticle de revueen_US
dc.identifier.doi10.1016/j.jfo.2022.09.034en_US
dc.subject.halSciences du Vivant [q-bio]/Santé publique et épidémiologieen_US
dc.identifier.pubmed36740463en_US
bordeaux.journalJournal Français d'Ophtalmologieen_US
bordeaux.page369-376
bordeaux.volume46
bordeaux.hal.laboratoriesBordeaux Population Health Research Center (BPH) - UMR 1219en_US
bordeaux.issue4
bordeaux.institutionUniversité de Bordeauxen_US
bordeaux.institutionINSERMen_US
bordeaux.teamLEHA_BPHen_US
bordeaux.peerReviewedouien_US
bordeaux.inpressnonen_US
hal.identifierhal-04029970
hal.version1
hal.date.transferred2023-03-15T10:45:06Z
hal.exporttrue
dc.rights.ccPas de Licence CCen_US
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.title=Comparaison%20des%20moyens%20clinique%20et%20d%E2%80%99imagerie%20disponibles%20en%20pratique%20clinique%20pour%20objectiver%20la%20pr%C3%A9sence%20de%20l%E2%80%99implant&rft.atitle=Comparaison%20des%20moyens%20clinique%20et%20d%E2%80%99imagerie%20disponibles%20en%20pratique%20clinique%20pour%20objectiver%20la%20pr%C3%A9sence%20de%20l%E2%80%99implan&rft.jtitle=Journal%20Fran%C3%A7ais%20d'Ophtalmologie&rft.date=2023-04&rft.volume=46&rft.issue=4&rft.spage=369-376&rft.epage=369-376&rft.eissn=1773-0597%20(Electronic)%200181-5512%20(Linking)&rft.issn=1773-0597%20(Electronic)%200181-5512%20(Linking)&rft.au=JOMAA,%20Emilie&KOUDSIE,%20S.&GONTIER,%20Brigitte&ROUGIER,%20Marie%20Benedicte&GATTOUSSI,%20Sarra&rft.genre=article


Archivos en el ítem

ArchivosTamañoFormatoVer

No hay archivos asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem