Mostrar el registro sencillo del ítem

dc.rights.licenseopenen_US
dc.contributor.authorARMENTIA, Mikel
dc.contributor.authorABASOLO, Mikel
dc.contributor.authorCORIA, Ibai
hal.structure.identifierInstitut de Mécanique et d'Ingénierie [I2M]
dc.contributor.authorSAINITIER, Nicolas
dc.date.accessioned2023-02-24T14:04:04Z
dc.date.available2023-02-24T14:04:04Z
dc.date.issued2022-01-31
dc.identifier.issn0022-3913en_US
dc.identifier.urihttps://oskar-bordeaux.fr/handle/20.500.12278/172091
dc.description.abstractEnStatement of problem Dental implant geometry affects the mechanical performance and fatigue behavior of butt-joint implant-supported restorations. However, failure of the implant component has been generally studied by ignoring the prosthetic screw, which is frequently the critical restoration component. Purpose The purpose of this in vitro study was to evaluate the effect of 3 main implant geometric parameters: the implant body diameter, the platform diameter, and the implant-abutment connection type (external versus internal butt-joint) on the fatigue life of the prosthetic screw. The experimental values were further compared with the theoretical ones obtained by using a previously published methodology. Material and methods Four different designs of direct-to-implant dental restorations from the manufacturer BTI were tested. Forty-eight fatigue tests were performed in an axial fatigue testing machine according to the International Organization for Standardization (ISO) 14801. Linear regression models, 95% interval confidence bands for the linear regression, and 95% prediction intervals of the fatigue load-life (F-N) results were obtained and compared through an analysis of covariance (ANCOVA) to determine the influence of the 3 parameters under study on the fatigue behavior (α=.05). Results Linear regression models showed a statistical difference (P<.001) when the implant body diameter was increased by 1 mm; an average 3.5-fold increase in fatigue life was observed. Increasing the implant abutment connection diameter by 1.4 mm also showed a significant difference (P<.001), leading to 7-fold longer fatigue life on average. No significant statistical evidence was found to demonstrate a difference in fatigue life between internal and external implant-abutment connection types. Conclusions Increasing the implant platform and body diameter significantly improved (P<.001) the fatigue life of the prosthetic screw, whereas external and internal connections provided similar results. In addition, experimental results proved the accuracy of the fatigue life prediction methodology.
dc.language.isoENen_US
dc.rightsAttribution 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/us/*
dc.title.enEffect of the geometry of butt-joint implant-supported restorations on the fatigue life of prosthetic screws
dc.title.alternativeThe Journal of Prosthetic Dentistryen_US
dc.typeArticle de revueen_US
dc.identifier.doi10.1016/j.prosdent.2021.12.010en_US
dc.subject.halSciences de l'ingénieur [physics]/Matériauxen_US
bordeaux.journalThe Journal of Prosthetic Dentistryen_US
bordeaux.page477.e1-477.e9en_US
bordeaux.volume127en_US
bordeaux.hal.laboratoriesInstitut de Mécanique et d’Ingénierie de Bordeaux (I2M) - UMR 5295en_US
bordeaux.issue3en_US
bordeaux.institutionUniversité de Bordeauxen_US
bordeaux.institutionBordeaux INPen_US
bordeaux.institutionCNRSen_US
bordeaux.institutionINRAEen_US
bordeaux.institutionArts et Métiersen_US
bordeaux.peerReviewedouien_US
bordeaux.inpressnonen_US
hal.identifierhal-04004050
hal.version1
hal.date.transferred2023-02-24T14:04:13Z
hal.exporttrue
dc.rights.ccCC BYen_US
bordeaux.COinSctx_ver=Z39.88-2004&amp;rft_val_fmt=info:ofi/fmt:kev:mtx:journal&amp;rft.jtitle=The%20Journal%20of%20Prosthetic%20Dentistry&amp;rft.date=2022-01-31&amp;rft.volume=127&amp;rft.issue=3&amp;rft.spage=477.e1-477.e9&amp;rft.epage=477.e1-477.e9&amp;rft.eissn=0022-3913&amp;rft.issn=0022-3913&amp;rft.au=ARMENTIA,%20Mikel&amp;ABASOLO,%20Mikel&amp;CORIA,%20Ibai&amp;SAINITIER,%20Nicolas&amp;rft.genre=article


Archivos en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem