Cross-validation on saplings of High-Capacity Tensiometer and Thermocouple Psychrometer for continuous monitoring of xylem water potential
DAINESE, Roberta
University of Strathclyde [Glasgow]
Botanique et Modélisation de l'Architecture des Plantes et des Végétations [UMR AMAP]
Voir plus >
University of Strathclyde [Glasgow]
Botanique et Modélisation de l'Architecture des Plantes et des Végétations [UMR AMAP]
DAINESE, Roberta
University of Strathclyde [Glasgow]
Botanique et Modélisation de l'Architecture des Plantes et des Végétations [UMR AMAP]
University of Strathclyde [Glasgow]
Botanique et Modélisation de l'Architecture des Plantes et des Végétations [UMR AMAP]
FOURCAUD, Thierry
Botanique et Modélisation de l'Architecture des Plantes et des Végétations [UMR AMAP]
Département Systèmes Biologiques [Cirad-BIOS]
< Réduire
Botanique et Modélisation de l'Architecture des Plantes et des Végétations [UMR AMAP]
Département Systèmes Biologiques [Cirad-BIOS]
Langue
en
Article de revue
Ce document a été publié dans
Journal of Experimental Botany. 2022, vol. 73, n° 1, p. 400-412
Oxford University Press (OUP)
Résumé en anglais
Abstract The Pressure Chamber, the most popular method used to measure xylem water potential, is a discontinuous and destructive technique and therefore not suitable for automated monitoring. Continuous non-destructive ...Lire la suite >
Abstract The Pressure Chamber, the most popular method used to measure xylem water potential, is a discontinuous and destructive technique and therefore not suitable for automated monitoring. Continuous non-destructive monitoring could only be achieved until very recently via the Thermocouple Psychrometer (TP). We here present the High-Capacity Tensiometer (HCT) as alternative method for continuous non-destructive monitoring. This provided us with a unique chance to cross-validate the two instruments by installing them simultaneously on the same sapling stem. The HCT and the TP showed excellent agreement for xylem water potential < -0.5 MPa. Response to day/night cycles and watering was remarkably in phase, indicating excellent response time of both instruments despite substantially different working principles. For xylem water potential > -0.5 MPa, the discrepancies sometimes observed between the HCT and TP were mainly attributed to the kaolin paste used to establish contact between the xylem and the HCT, which becomes hydraulically poorly conductive in this range of water potential once dried beyond its air-entry value and subsequently re-wetted. Notwithstanding this limitation, which can be overcome by selecting a clay paste with higher air-entry value, the HCT has been shown to represent a valid alternative to the TP.< Réduire
Mots clés en anglais
High-Capacity Tensiometer
Pressure Chamber
Thermocouple Psychrometer
Xylem water potential
Water tension
Water status monitoring
Origine
Importé de halUnités de recherche