Afficher la notice abrégée

hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorAGUER, P.
dc.contributor.authorALVES, L.C.
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorBARBERET, P.
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorGONTIER, E.
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorINCERTI, S.
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorMICHELET-HABCHI, C.
dc.contributor.authorKERTÉSZ, Z.
dc.contributor.authorKISS, A.Z.
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorMORETTO, P.
dc.contributor.authorPALLON, J.
dc.contributor.authorPINHEIRO, T.
dc.contributor.authorSURLÈVE-BAZEILLE, J.E.
dc.contributor.authorSZIKSZAI, Z.
dc.contributor.authorVERISSIMO, A.
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorYNSA, M.D.
dc.date.issued2005
dc.identifier.issn0168-583X
dc.description.abstractEnThe use of on-axis geometry in scanning transmission ion microscopy (STIM) has been widely used for thin biological sample structure identification. In this configuration, the lateral resolution is optimised so that micron or sub-micron beam spots are easily achieved even for classic microbeam lines. Off-axis STIM was more particularly employed for rapid imaging, and also (when associated to a scattering set-up) for normalising elemental contents obtained by other ion beam analysis techniques in organic thin samples. Due to the very small beam current required, on-axis STIM is a stand-alone technique. Off-axis STIM can be advantageous as it enables the simultaneous utilisation of PIXE and RBS techniques. In this paper, the STIM images obtained with an on-axis geometry, a standard off-axis geometry and a recently developed on–off geometry are presented and discussed. Data from skin samples are used for comparison purposes aiming at studying skin permeability to sunscreens. Skin is a stratified tissue and the precise identification of skin layers is needed to ascertain the penetration depth of the physical filter from the formulation. In addition to the intrinsic difference in image quality due to the beam resolution, the influence of the detector type, implanted silicon detector versus Si pin diode, is discussed on the basis of their energy resolution, their resistance to beam damage as well as the effect of the sample thickness in the final image obtained. Data reduction software is also presented for the different geometries and the effect of parameters such as median or mean energy on the image quality is shown.
dc.language.isoen
dc.publisherElsevier
dc.title.enSkin morphology and layer identification using different STIM geometries
dc.typeArticle de revue
dc.identifier.doi10.1016/j.nimb.2005.01.073
dc.subject.halPhysique [physics]/Physique [physics]/Biophysique [physics.bio-ph]
bordeaux.journalNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
bordeaux.page292-299
bordeaux.volume231
bordeaux.peerReviewedoui
hal.identifierin2p3-00024126
hal.version1
hal.popularnon
hal.audienceNon spécifiée
hal.origin.linkhttps://hal.archives-ouvertes.fr//in2p3-00024126v1
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Nuclear%20Instruments%20and%20Methods%20in%20Physics%20Research%20Section%20B:%20Beam%20Interactions%20with%20Materials%20and%20Atoms&rft.date=2005&rft.volume=231&rft.spage=292-299&rft.epage=292-299&rft.eissn=0168-583X&rft.issn=0168-583X&rft.au=AGUER,%20P.&ALVES,%20L.C.&BARBERET,%20P.&GONTIER,%20E.&INCERTI,%20S.&rft.genre=article


Fichier(s) constituant ce document

FichiersTailleFormatVue

Il n'y a pas de fichiers associés à ce document.

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée